EasyManua.ls Logo

SICK LMS500 Series - Page 93

SICK LMS500 Series
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
LMS500 Product Family
Annex
8013796/UL20/2010-09-27 © SICK AG · Division Auto Ident · Germany · Subject to change without notice 93
Chapter 10
10.2.11 Save data permanently
Via the message, the parameters are saved in the EEPROM of the system configuration plug
and will also be available after the device is switched off and on again.
Important The required user level is “Authorised client” (see section 10.2.7 “Select user level/login”
o
n page 87).
Request
Message structure: sMN mEEwriteall
Answer
Message structure: sAN mEEwriteall ErrorCode
Example
Request: <STX>sMN{SPC}mEEwriteall<ETX>
HEX string: 02 73 4D 4E 20 6D 45 45 77 72 69 74 65 61 6C 6C 03
Answer: <STX>sAN{SPC}mEEwriteall{SPC}1<ETX>
HEX string: 02 73 41 4E 20 6D 45 45 77 72 69 74 65 61 6C 6C 20 31 03
Message part Description Variable type Length
(byte)
Value range
Type of command Request (SOPAS method by name) string 3 sMN
Command Save data permanently string 11 mEEwriteall
Message syntax XXIII: Request “Save data permanently”
Message part Description Variable type Length
(byte)
Value range
Type of command Answer (SOPAS answer) string 3 sAN
Command Save data permanently string 11 mEEwriteall
ErrorCode The command has been accepted
if the error code 1 is returned.
bool_1 1 0 error
1 no error
Message syntax XXIV: Answer to the “Save data permanently” request

Table of Contents