Figure 56: Enabling or disabling Component Selector
NOTE
The Component Enable checkbox must be selected for at least one Component Selector, i.e.
Range, Reflectance and/or Scatter.
9.2.7.5 Enabling reflectance measurements
Workflow step: Data collection
To enable collection of laser reflectance values in addition to the range data, follow the
steps below.
1. Open the Parameter editor and select the ImageFormatControl category.
2. Set RegionSelector to Scan3dExtraction1.
3. Set ComponentSelector to Reflectance.
4. Select the Component Enable checkbox.
To view the image with laser reflectance, select Reflectance or Reflectance (Hybrid) from
the View list. see "View modes", page 68 for details.