NOTE
For best image quality, make sure that the whole width of the laser line is within the
region.
1. Select the Show active sensor area checkbox in the Settings section in the right part of
the GUI.
A blue overlay appears in the 2D image (see figure 55). The overlay represents
the parts of the image to be excluded from the generation of 3D image data. The
remaining dark area is the extraction area (corresponding to Region1).
Figure 55: 2D image with blue overlay
2. Hover over the extraction area to highlight its handles.
3. Click and drag the handles to change the dimensions and offset for Region1:
°
Click and drag the middle handle to adjust the OffsetY and OffsetX parameters.
°
Click and drag the side handles to adjust the Height and Width parameters.
When a handle is moved, the corresponding parameter values in the Parameter editor
are automatically updated. As an alternative to moving the handles, the parameter
values can be changed directly in the Parameter editor.
Increasing the number of rows
The camera acquires 12-bits data as default, which means that the maximum height
of Region1 is 256 rows. To increase the maximum number of rows, you must switch to
16-bits data, according to the steps below:
1. In the Parameter editor, set RegionSelector to Scan3dExtraction1.
2. Set ComponentSelector to Range.
3. Set PixelFormat to Coord3D_C16.
9.2.7.4 Enabling or disabling range measurements
Workflow step: Data collection
The range measurements are enabled by default. To enable or disable range measure‐
ments, follow the steps below:
1. Open the Parameter editor and select the Image Format Control category.
2. Set RegionSelector to Scan3dExtraction1.
3. Set ComponentSelector to Range.
4. Select or deselect the Component Enable checkbox.
9 OPERATION
62
O P E R A T I N G I N S T R U C T I O N S | Ranger3 8020774/1D7Q/2022-03 | SICK
Subject to change without notice