Procedure
1.
Click the "Process engineering > PipeSpec Manager" category.
2. Optional: Change the defaults in the "Link between P&ID and pipe part catalog" control 
group.
Field Description
"Pipe spec" Defines the attribute in which the pipe spec of a P&ID 
object is specified.
 
"Nominal diameter specification for the 
first connector (input)"
Defines which attribute saves the input nominal diame‐
ter of the P&ID object.
"Nominal diameter specification for other 
connector (output)"
Defines which attribute saves the output nominal diam‐
eter of the P&ID object.
"Attribute for function code" Fixed programmed. Changes have no effect.
Defines which attribute saves the function code of the 
pipe part catalog object.
See 
also chapter Checking the attribute for the function 
code (Page 129).
"Attribute for P&ID function code" Defines which attribute saves the P&ID function code of 
the P&ID object.
See also chapter 
Checking the attribute for the P&ID 
function code (Page 128).
11.7 Configuring P&ID base objects
11.7.1
Workflow
The P&ID catalog supplied with the database contains all settings necessary for the link 
between the P&ID catalog, the pipe part catalog, and 3D.
Procedure
If you have created your own P&ID catalog or made major changes or additions to the catalog 
supplied with the database, you must ensure that all objects have the settings necessary for 
the link. 
To do this, proceed as follows for every P&ID base object:
1. Check whether the P&ID base object is defined as a request:
Properties, "System settings" tab, "Implement requests" control group: The "Request" 
option is activated.
2. If the P&ID base object has the "3D geometry" tab, delete or rename it.
Reason: The 3D functionality should not be derived from the P&ID object but instead from 
the pipe part catalog implementation.
P&ID 3D pipe part catalog interaction
11.7 Configuring P&ID base objects
PipeSpec Designer
Operating Manual, 09/2014, A5E32076948-AA 127