Result
A pipe spec element is created under the pipe spec in the base data.
The pipe spec element receives a base object reference to the pipe part from the pipe part
catalog. This means it inherits from the catalog part.
The pipe spec element has the "Application limits component" tab. It stores data for the
nominal diameter range of the pipe spec element.
Nested classes
To embed one pipe spec in another pipe spec, drag&drop the corresponding base object from
the Navigator to the "Pipe parts" tab.
See also
Updating attachment type combinations (Page 107)
8.4.3 Navigating to the pipe part
You can navigate from the pipe part table to the base data.
Procedure
1. Select the pipe spec element in the pipe part table.
2. Select the following command from the context menu:
To navigate to the pipe spec element: "Navigate - pipe spec"
To navigate to the pipe part in the pipe part catalog on which the pipe spec element is
based: "Navigate - original"
8.4.4 Setting the upper and lower limits of the DN range of a pipe part
Procedure
1. Select the pipe part in the pipe part table.
2. Define the lower limit in the "Nominal diameter from" column and the upper limit in the
"Nominal diameter to" column.
3. Save your entries.
Configuring pipe specs
8.4 Configuring the "Components" tab