The lower area
The table in the lower area meets the following functions:
Provides
an overview of the nominal diameters in which the pipe parts of the pipe part type
are currently available.
Provides an overview in which nominal diameters the pipe parts of the pipe part type are
basically permitted.
Changing the nominal diameter of the pipe parts.
The table is structured as follows:
Left column: The legend descriptions of the pipe parts
The remaining header columns: The current nominal diameter range of the pipe spec
Each row describes the nominal diameter range of a pipe part:
White cell with check mark: The nominal diameter is currently available.
White cell without check mark: The nominal diameter is always available.
Gray cell: This nominal diameter cannot be within the nominal diameter range.
Context menus
The context menu for the upper table contains the following entries:
A list of all pipe parts which are available as preselected components for the current nominal
diameter
"Legend"
The context menu for the lower table contains the following entries:
"Select"
"Deselect"
"Navigate"
8.5.2 Preselected components
Definition
Preselected components are those pipe parts returned by COMOS as standard values when
the pipe part type is addressed.
Example: A user is working on an isometric drawing and places a pipe part using the symbol
bar of the isometric drawing. The user selects a pipe part type and places the pipe part that is
set as preselected component for the pipe part type and the selected nominal diameter.
Configuring pipe specs
8.5 "Nominal diameters" tab:
PipeSpec Designer
92 Operating Manual, 09/2014, A5E32076948-AA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens COMOS and is the answer not in the manual?

Siemens COMOS Specifications

General IconGeneral
ManufacturerSiemens
DescriptionCOMOS is plant engineering software for the process industry. It manages plant projects and documentation. It covers the entire plant lifecycle from engineering and design to operation and maintenance.
FunctionalityPlant design and engineering
IntegrationIntegrates with Siemens TIA Portal, SIMATIC PCS 7, and other third-party systems
Data ManagementCentralized data management
ModulesIncludes modules for process engineering, electrical engineering, instrumentation, and automation
CollaborationSupports multi-disciplinary team collaboration with role-based access
DocumentationAutomated generation of documentation (e.g., P&IDs, loop diagrams, instrument lists), document management, version control.
CustomizationHighly customizable to meet specific project requirements and industry standards. Allows for scripting and API integration.
Industry StandardsISO, IEC

Related product manuals