3.5.8 "Datasheet" tab
Saves part-specific data dependent upon the nominal diameter
3.5.8.1
Control group "Manufacturer data"
Attributes
The control group contains auxiliary fields, which can be used in reports, for example:
3.5.8.2 Nominal size dependent table
Contents of nominal size dependent table
The table saves part-specific data dependent upon the nominal diameter:
Physical data (weight, volume, friction losses)
Norm object data for linking with ERP systems (part number, overall material number for
Merian, SAP-specific data)
Other data that is relevant for the interfaces (material class, part ID, storage number, order
numbers, STYPE).
Properties of the nominal diameter column(s)
The properties and values of the nominal diameter columns are inherited across several levels
of the standard geometry tables. They are entered manually there.
Do not change the values directly at the pipe part.
"DN1" column
"DN2" column
3.5.9 "Local dimensions (NPS)" tab
For pipe parts with one nominal diameter:
"Local Dimensions (DN)"
For pipe parts with two nominal diameters:
"Local Dimensions (DN1/DN2)"
Preparing for creation and maintenance of pipe specs
3.5 Administering pipe part catalogs
PipeSpec Designer
Operating Manual, 09/2014, A5E32076948-AA 47