Attributes
  "Minimum" "Maximum" "<1-6>"
Pressure range Nominal pressure Nominal pressure
Here, the same value as 
shown in the "Minimum" col‐
umn must be entered.
Permissible nominal pres‐
sure 
for the specified temper‐
ature values
Temperature range Minimum temperature at 
which 
the associated nominal 
pressure remains constant.
Maximum temperature at 
which the associated nominal 
pressure remains constant.
 
Selected temperature values
3.5.7.2 Control group "Materials – List of objects"
Attributes
Control element Description 
"Material" Script block "OnChange":
●
Purpose: Sets the material number depending on the material and adds the 
material to the Navigator description.
● See also chapter Navigator description from pipe part attributes (Page 150).
"NSys"
● Defines the system of standards for the component
●
Controls all the component's attributes that are dependent on the system of 
standards.
● Registered as dependent attributes: "VS001", "VS002"
"Position" Table in which the individual parts of the pipe part are described.
See also
Change DisplayValue()
 (Page 149)
3.5.7.3 Control group "Technical Terms of Delivery"
Attributes
Control element Description
"Standard" The standard for the technical terms of delivery, depending on the sys‐
tem of standards
"No." Table in which the individual parts of the pipe part are described with 
regard to their technical terms of delivery.
Preparing for creation and maintenance of pipe specs
3.5 Administering pipe part catalogs
PipeSpec Designer
46 Operating Manual, 09/2014, A5E32076948-AA