Field "Start object":
A link to one of the following base objects:
Pipe part from the pipe part catalog
Structure object from the pipe part catalog
Pipe spec element
Pipe spec
If there are no base objects underneath the start object, the start object is analyzed.
If there are more base objects underneath the start object, they are analyzed recursively.
"Unit location" field:
Link to an engineering object of the "Device" system type whose creation mode is "Free"
and which has the "Coordinate system definition" tab
Optional
Requirement: "Create 3D" option is activated.
The 3D objects generated are created underneath the object linked here.
"Error geometry" field:
Link to a 3D base object
Optional
Requirement: The "Create 3D" option is activated and the "Unit location" reference is
set.
For objects whose geometry could not be calculated or could not be calculated correctly,
3D objects are generated with the base object linked here.
"Create 3D" option:
Optional
Requirement: "Unit location" reference is set.
Active: 3D objects are created for all objects, even objects whose geometry was not
calculated correctly. The 3D objects can be displayed in the Viper 3D Editor.
"Invalid only" option:
Optional
Requirement: "Create 3D" option is activated.
Active: 3D objects are only created for the objects whose geometry could not be
calculated correctly.
"Start analysis" button:
Starts the analysis. Data is written to the results table even while the analysis is still in
progress.
"Cancel" button:
Cancels the analysis.
"Error analysis for 3D objects" plugin