EasyManua.ls Logo

Siemens FLENDER K SH Series - Interior Preservation with Preservative Agent; Interior Preservation with Castrol Alpha SP 220 S

Siemens FLENDER K SH Series
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23 / 109
BA 5846 en 05/2015
Note
Unless otherwise contractually agreed, the durability periods of the interior gearunit preservation
specified in table 2 or 3 will apply, provided the related requirements are adhered to. The durability period
for the exterior preservation and the related requirements can be found in table 4.
The guarantee period starts on the date of delivery or that of the notice that the item is ready for shipment.
In case of a storage period other than the durability periods indicated in tables 2 or 3 and in table 4, the
interior and the exterior preservation must be checked and, as necessary, be renewed (see items 7.3.1
and 7.3.2).
4.4.1 Interior preservation with preservative agent
Note
Depending on the operating oil (oil type and viscosity), as indicated on the rating plate, the gear units
have been preserved with the preservative agent specified in table 2 or table 3.
4.4.1.1 Interior preservation with "Castrol Alpha SP 220 S"
Table 2: Durability period and measures for interior preservation when using mineral oil or PAObased
synthetic oil
Durability period
Preservative agent Special measures
up to 6 months
Castrol Alpha SP 220 S
None
up to 24 months
Seal all holes on the gear unit.
Replace the air filter or wetair filter with
a screw plug. (Replace the screw plug
with the air filter or wetair filter before
startup.)
Seal the labyrinth seal on the output
shaft with adhesive tape. (Prior to
startup remove the adhesive tape.)
For storage periods longer than 24 months, renew the preservation (see item 4.4.1.3).

Table of Contents