84 / 109
BA 5846 en 05/2015
Top up gearunit oil through the hole up to just beneath the air filter or wetair filter.
Note
For gearunit oils, refer to table "T 7300" (for a link to the Internet, see the back cover).
CAUTION
Risk of injury through chemical substances
The oil must not come into contact with the skin (e.g. the operator’s hands).
The safety notes on the data sheets for the oil used must be observed.
Remove any oil spillage immediately with a binding agent.
Observe manufacturer’s instructions for handling lubricants and binding agents.
Wear suitable protective clothing.
Place the inspection and/or assembly cover with the seal on the housing.
Screw in the fastening screws of the inspection and/or assembly cover and tighten them to the specified
tightening torque (see item 6.19).
Replace the air filter and reducing screw or wetair filter with a screw plug.
7.3.1.2 Interior preservation with preservative agent
Before longer shutdown periods gear units with forcefeed lubrication systems, oilcirculation cooling
and/or noncontacting shaft seals should be filled with preservative agent and run without load.
Place a suitable container under the oildrain point of the gearunit housing.
Unscrew the oildrain plug and/or open the oildrain cock.
Drain the operating oil into a suitable container (see section 10, "Maintenance and Repair").
WARNING
Risk of scalding
Serious injury through escaping operating media possible whilst they are replaced.
Wear suitable protective gloves, protective glasses and protective clothing.
CAUTION
Risk of injury through chemical substances
The oil must not come into contact with the skin (e.g. the operator’s hands).
The safety notes on the data sheets for the oil used must be observed.
Remove any oil spillage immediately with a binding agent.
Wear suitable protective clothing.
Note
Check the condition of the sealing ring; the sealing ring is vulcanised onto the oildrain plug. If necessary,
use a new oildrain plug.
Close the oildrain cock and/or screw in the oildrain plug again.