86 / 109
BA 5846 en 05/2015
7.3.1.3 Interior preservation with "Castrol Alpha SP 220 S" preservative agent
• Place a suitable container under the oildrain point of the gearunit housing.
• Unscrew the oildrain plug and/or open the oildrain cock.
• Drain the oil into a suitable container (see section 10, "Maintenance and Repair").
WARNING
Risk of scalding
Serious injury through escaping operating media possible whilst they are replaced.
Wear suitable protective gloves, protective glasses and protective clothing.
CAUTION
Risk of injury through chemical substances
The oil must not come into contact with the skin (e.g. the operator’s hands).
The safety notes on the data sheets for the oil used must be observed.
Remove any oil spillage immediately with a binding agent.
Observe manufacturer’s instructions for handling lubricants and binding agents.
Wear suitable protective clothing.
Note
Check the condition of the sealing ring; the sealing ring is vulcanised onto the oildrain plug. If necessary,
use a new oildrain plug.
• Shut the oildrain cock and/or screw in the oildrain plug again.
• Unscrew the air filter or wetair filter on the top of the housing.
• Replace the air filter or wetair filter with a screw plug.
Note
Carefully clean the air filter (see item 10.2.4) and keep it on a safe place (it will be required again when
starting up again) or use a new wetair filter at startup.
• Remove any dirt in the area of the inspection and/or assembly cover or that of the marked oilfilling
point.
• Undo and remove the fastening screws of the inspection and/or assembly cover.
• Remove the cover with the seal from the housing; the seal will be used again.
• Fill the gear unit with "Castrol Alpha SP 220 S" (see table 2 in item 4.4.1.1).
Determine the filling quantity (10 %) according to the gearunit dimensions: length x width x height x 0.1.
NOTICE
Material damage
Corrosion possible through use of an unsuitable preservative agent.
Use special oil "Castrol Alpha SP 220 S" with additional anticorrosive agent (additive "S").