EasyManua.ls Logo

Siemens FLENDER K SH Series - Operation Guidelines; General Operating Principles

Siemens FLENDER K SH Series
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
88 / 109
BA 5846 en 05/2015
8. Operation
Observe the instructions in section 3, "Safety instructions", in section 9, "Faults, causes and remedy", and
in section 10, "Maintenance and repair"!
8.1 General
To achieve a satisfying and troublefree operation of the equipment, be certain to observe the operating
values specified in section 1, "Technical Data", as well as the information given in the operating instructions
of the oilsupply system.
DANGER
Electrostatic discharge
Danger to life through ignition of any potentially explosive atmosphere through electrostatic discharge.
The coating must not carry an electrostatic charge.
The operator must ensure that highly effective mechanisms which can set up a charge in the coating are
safely avoided.
During operation the gear unit must be monitored for the following:
Operating temperature The maximum permitted temperature is:
90 °C
At higher temperatures the gear unit must be shut down
immediately and Siemens customer service consulted.
Oil pressure of the oil-supply
system
Minimum 0.5 bar
Water pressure of the cooling coil Maximum 8 bar
Changes in gear noise
Oil leakage at the housing and
shaft seals
Bearing vibrations, with fitted
measuring device

Table of Contents