70 / 109
BA 5846 en 05/2015
6.18 Final work
□ After installation of the gear unit check all screw connections for tight fit.
□ Check the alignment after tightening the fastening elements. The alignment must not have been
changed.
□ Check that all the devices which have been demounted for transport reasons have been refitted.
For this refer to the details on the data sheet, in the list of equipment and on the associated drawings.
DANGER
Risk of explosion
Ignition of a potentially explosive atmosphere possible through overheating of the gear unit in case of too
low oil level due to leakage.
Any oildrain cocks must be secured against accidental opening.
If an oilsight glass is used for monitoring the oil level, it must be protected against damage.
□ The gear unit must be protected against falling objects.
□ Protective devices for rotating parts must be checked for correct seating. Contact with rotating parts
is not permitted.
DANGER
Electrostatic discharge
Danger to life through ignition of any potentially explosive atmosphere through electrostatic discharge.
A potential equalisation in accordance with the applying regulations and/or directives must be carried
out.
On the gear units threaded holes are available for establishing an earth connection. This work must
always be done by specialist electricians.
□ Cable entries must be protected against moisture.