24 / 109
BA 5846 en 05/2015
4.4.1.2 Interior preservation with "Castrol Tribol 1390 / 220"
Table 3: Durability period and measures for interior preservation when using PGbased synthetic oil
Durability period
Preservative agent Special measures
up to 6 months
Special anticorrosion oil
TRIBOL 1390
1)
None
up to 36 months
Seal all holes on the gear unit.
Replace the air filter or wetair filter with
a screw plug. (Replace the screw plug
with the air filter or wetair filter before
startup.)
Seal the labyrinth seal on the output
shaft with adhesive tape. (Prior to
startup remove the adhesive tape.)
For storage periods longer than 36 months, renew the preservation (see item 4.4.1.3).
1)
Resistant to tropical conditions and sea water; maximum ambient temperature 50 °C
Note
The procedure for interiorpreservation treatment is described in section 7 (see item 7.3.1).
4.4.1.3 Represerving the interior of the gear unit in case of longer periods of storage
CAUTION
Risk of injury
Risk of injury to eyes or hands through chemically aggressive operating media.
Wear suitable protective glasses and protective gloves.
Remove any oil spillage immediately with a binding agent.
For storage periods longer than 24 months (see table 2) or 36 months (see table 3), the interior
preservation of the gear unit must be renewed. The following procedure is recommended:
Remove any dirt in the area of the inspection and/or assembly cover or that of the marked oilfilling
point.
Undo and remove the fastening screws of the inspection and/or assembly cover.
Remove the cover with the seal from the housing (the seal must not be damaged, it will be used again).
Place a suitable container under the oildrain point of the gearunit housing.
Unscrew the oildrain plug and/or open the oildrain cock and drain the used preservation oil into
a suitable container.
Dispose of the residue of the preservative oil in accordance with regulations.
Shut the oildrain cock and/or screw in the oildrain plug.
Fill the gear unit with "Castrol Alpha SP 220 S".
Determine the filling quantity according to the gearunit dimensions: length x width x height x 0.05.
NOTICE
Material damage
Corrosion possible through use of an unsuitable preservative agent.
Use special oil "Castrol Alpha SP 220 S" with additional anticorrosive agent (additive "S").

Table of Contents