Place the inspection and/or assembly cover with the seal on the housing.
Screw in the fastening screws of the inspection and/or assembly cover and tighten them to the specified
tightening torque (see item 6.19).
NOTICE
Material damage
Corrosion possible through leaving the gear unit open too long.
Close the gear unit airtightly at the latest one hour after opening.
Before restarting the gear unit take the following measure:
Replace the screw plug with the air filter or wetair filter.
7.3.2 Exterior preservation
7.3.2.1 Exteriorpreservation procedure
Clean the surfaces.
NOTICE
Material damage
Risk of damage to the shaftsealing ring through contact with chemically aggressive preservative agent.
For separation between the sealing lip of the radial shaftsealing ring and the preservative agent, the
shaft should be brushed with grease in the area around the sealing lip.
Apply preservative agent.
Note
For preservative agent, see table 4 in item 4.4.2.