BA 5846 en 05/2015
Faults RemedyCauses
Increased temperature at
backstop.
Locking function fails.
Damage to backstop. Contact Customer Service.
Check and, if necessary,
replace backstop.
Main drive motor does not
start.
Incorrect direction of rotation of the
motor.
Incorrect installation and/or defect
of cage with sprags of backstop.
Change polarity of motor.
Contact Customer Service.
Fit cage of the backstop turned by
180° or replace.
Changeover of the gear unit Contact Customer Service.
Check shifting device of the gear
unit; replace, if necessary.
Fault in the oilsupply system. Consult operating instructions
for oilsupply system.
NOTICE
Material damage
Risk of damage to the gear unit through use of operating oils of insufficient quality.
The quality of the oil used must comply with the requirements specified in the separately supplied
BA 7300 operating instructions.