Table 17: Maintenance and repair work
Measures Periods Remarks
Check the oil temperature Daily See items 7.2.5 and 8.1.
Check for unusual gear-unit noise Daily
Check the oil level Monthly and before each start Middle of the oil-sight glass
Middle between the marks
on the oil-level indicator
Upper mark on the dipstick
Comparison of vibration values for
bearing monitoring with initial values
(reference values) on starting up
Every 3000 operating hours See item 7.2.7.
The proper function and
measurement accuracy of the
ignition-prevention system for the
temperature monitoring should be
checked at regular intervals
according to the instructions of the
manufacturer of the
ignition-prevention device.
See instructions of the manufacturer The operator must ensure
this.
Check the gear unit for leaks Monthly
Examine the water content of the oil After approx. 400 operating hours,
at least once a year
See item 10.2.1.
Perform the first oil change Approx. 400 operating hours
after start-up
See item 10.2.2.
Perform subsequent oil changes Every 24 months
or 10 000 operating hours.
See items 10.2.2 and 10.1.1.
Replace the wet-air filter As required See item 10.2.3.
Clean the air filter Every 3 months See item 10.2.4.
Clean the fan and gear unit Depending on requirements,
at least every 2 years
See item 10.2.6.
Recharge grease to splines on
output shaft / spacer
Every 6 months
or 5000 operating hours
See item 10.2.7.
Repack grease in the Taconite seals Every 3000 operating hours,
at least every 6 months
See item 10.2.8.
Check cooling coil Every 2 years See item 10.2.9.
Check hose lines Yearly See item 10.2.10.
Replace hose lines 6 years from the manufacturing date
impressed
See item 10.2.10.
Check tightness of fastening bolts After approx. 400 operating hours,
thereafter every 2 years
See item 6.19.