Configuration using Web Based Management and Command Line Interface
4.5 The Switch menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
163
Syntax of the Command Line Interface
Table 4- 44 Current Unicast Filter - CLI\SWITCH\UCAST>
Command
Description
Comment
info Shows the content of the address table
of an IE switch.
-
find [VLAN-ID]<MAC ad-
dress> [S|L] [port]
Searches for a MAC address in the
address table of an IE switch. You can
also see the ports to which a received
frame with this (destination) address is
sent.
If you do not specify a VLAN-ID, all
VLANs are browsed for the specified
MAC address.
As an option, you can also specify a
port. Browsing is then restricted to the
specified port.
As a further option, you can also restrict
browsing to static and learned entries:
S
Static entries
L
Learned entries
-
add [VLAN-ID]<MAC ad-
dress> <port>
Inserts a static entry for a unicast ad-
dress in the address table.
Administrator only.
edit [VLAN-ID] <MAC ad-
dress> <port>
Changes an entry in the address table. Administrator only.
delete [VLAN-ID] <MAC
address>
Deletes a static entry from the address
table.
Administrator only.