Configuration using Web Based Management and Command Line Interface
4.5 The Switch menu
SCALANCE X-300 / X-400
190 Configuration Manual, 10/2014, C79000-G8976-C187-22
If the VLAN-ID of the port was defined dynamically using the "MAC Authentication" method
or "Guest LAN", the "Port VID" is configured automatically.
Acceptable Frames
This specifies how untagged frames are handled. The following alternatives are possible:
tagged only
The IE switch discards all untagged frames.
all
The IE switch forwards all frames.
Ingress Filtering
Here, you can see whether the VID of received frames is evaluated (entry enabled) or not
(entry disabled).
Trunk
This specifies whether a port was configured as a trunk port (entry enabled) or not (entry
disabled).
Configuration of a port for VLAN
After clicking on one of the entries in the Ports column, you change to the page for
configuring the port properties for receipt of frames:
Figure 4-79 VLAN Port Configuration
Port
This read-only box displays the slot and port number to which the information on this page
relates.
Port Priority
The priority assigned to untagged frames.
Port VLAN ID
The VLAN ID that is assigned to untagged frames.
If the VLAN ID of the port was defined dynamically with the "MAC Authentication" method or
"Guest VLAN", the "Port VLAN ID" is configured automatically.
Tagged Frames only
If you activate this option, untagged frames are discarded. Otherwise, the forwarding rules
apply according to the configuration.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals