Command
Description
Comment
autoedge [<T|F> [ports]] Specifies that a connected end device or con-
nected switch is detected automatically at the
relevant port:
• T
End device
• F
Switch
If a (rapid) spanning tree protocol is received, the
value "F" is displayed.
Administrator
only.
ptp [<A|T|F> [ports]] The point-to-point link establishes a direct link
between two switches.
Specifies whether or not the relevant port is a
PtP port:
• A
PtP is detected automatically. With full du-
plex, a PtP link is assumed, with half duplex
no PtP link.
• T
Specifies a PtP link, even though half duplex
is being used.
• F
Specifies no PtP link if duplex is being used.
Administrator
only.