EasyManuals Logo

Siemens SCALANCE X-400 Configuration Manual

Siemens SCALANCE X-400
404 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #218 background imageLoading...
Page #218 background image
Configuration using Web Based Management and Command Line Interface
4.5 The Switch menu
SCALANCE X-300 / X-400
218 Configuration Manual, 10/2014, C79000-G8976-C187-22
State
The "State" column shows the current status of the port.
The following statuses are possible:
disabled
The port only receives and is not involved in STP, MSTP and RSTP.
blocking
The port receives BPDUs.
listening
The port receives and sends BPDUs. The port is involved in the spanning tree
algorithm.
learning
Stage prior to the forwarding status, the port is actively learning the topology; in other
words, the node addresses.
forwarding
Following the reconfiguration time, the port is active again in the network; it receives
and forwards data frames.
Role
The "Role" column specifies which role the port adopts:
The following values are possible:
Root
The port has the lowest path costs from the device itself to the regional root bridge of
the MST instance.
Designated
Via this port, a connected network segment reaches the MSTI regional root bridge
with minimum path costs.
Alternate
The port is blocked and provides an alternative path to the MSTI regional root bridge.
Backup
The port is blocked and provides an alternative path to a collision domain that is
already connected via a different port.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals