Configuration using Web Based Management and Command Line Interface
4.5 The Switch menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
229
Syntax of the Command Line Interface
Table 4- 72 Fiber Monitoring Protocol - CLI\SWITCH\FMP>
Command
Description
Comment
info
Shows the FMP configuration.
limit [rx | loss] [req |
dem] [<port>] [<limit>]
Specifies the limits for the received power and the
power loss per port:
• rx
Received power
• loss
Power loss
• req
First notification
• dem
Second notification
• port
Port for which the settings apply
• limit
Value for the limit in 1/10 dBm (received power)
or 1/10 dB (power loss)
Administrator only
enable <D|E> [<Port>]
Enables / disables FMP for the specified port.
Administrator only
Table 4- 73 Fiber Monitoring - CLI\SWITCH\FM>
Command
Description
Comment
info Shows general information about the transceivers,
for example model, serial number and current
values, e.g. received and transmit power.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals