Configuration using Web Based Management and Command Line Interface
4.5 The Switch menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
229
Syntax of the Command Line Interface
Table 4- 72 Fiber Monitoring Protocol - CLI\SWITCH\FMP>
Command
Description
Comment
info
Shows the FMP configuration.
limit [rx | loss] [req |
dem] [<port>] [<limit>]
Specifies the limits for the received power and the
power loss per port:
rx
Received power
loss
Power loss
req
First notification
dem
Second notification
port
Port for which the settings apply
limit
Value for the limit in 1/10 dBm (received power)
or 1/10 dB (power loss)
Administrator only
enable <D|E> [<Port>]
Enables / disables FMP for the specified port.
Administrator only
Table 4- 73 Fiber Monitoring - CLI\SWITCH\FM>
Command
Description
Comment
info Shows general information about the transceivers,
for example model, serial number and current