Configuration using Web Based Management and Command Line Interface
4.3 The X-300/X-400 menu
SCALANCE X-300 / X-400
80 Configuration Manual, 10/2014, C79000-G8976-C187-22
(multiple errors), there may be an interruption of the standby link. This error indicates, for
example, a connection abort between standby partners or a device failure.
"Standby <partner's / observer's> state conflict resolved."
The status described above has been resolved, for example after eliminating a fault.
"Standby <partner / observer> conflicts with <master / slave> role."
The function signaled by the partner or observer conflicts with the local master/slave role.
This is the case when both standby devices adopt the same master/slave role in a ring on
or when both connected observers adopt roles that are not master/slave roles. The
integrity of the network is retained. In extreme situations (multiple errors), there may be
an interruption of the standby link. This error indicates, for example, a connection abort
between standby partners or a device failure.
"Standby <partner / observer> conflicts with <master / slave> role resolved."
The status described above has been resolved, for example after eliminating a fault.
"Standby <partner / observer> conflicts with observer <on / off> configuration."
The configuration signaled by the partner or observer conflicts with the module's own
current standby observer setting.
"Standby <partner / observer> observer configuration conflict resolved."
The status described above has been resolved; the configuration of the partner or
observer matches the module's own standby observer setting.
"Standby slave - at least one standby port has no link."
At least one standby port of the slave has no link.
If a standby port of the corresponding master fails in this status, the slave cannot
establish the connection via its standby port.
"Standby slave - all standby ports linked up."
The status described above has been resolved; all standby ports of the slave have a
connection.
The following event messages can occur:
"Standby observer function <started / stopped>."
The standby observer function was started or stopped.
"Standby function <started / stopped>."
The standby function was started or stopped.
"Standby - take on the <master / slave> role."
The master or slave role was adopted.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals