Configuration using Web Based Management and Command Line Interface
4.4 The Agent menu
SCALANCE X-300 / X-400
88 Configuration Manual, 10/2014, C79000-G8976-C187-22
If an IE switch has an IP address and there is an Ethernet connection to a PC or PG, follow
the steps below to download configuration data:
1. Open a console window and type in the command ftp followed by the IP address of the IE
switch. Example:
ftp 192.168.20.54
2. For the login and password enter the same values as you use for WBM and CLI.
3. Enter the "put" command followed by the name of the firmware file.
Example:
put cfgdata.txt
4. Once the file has been loaded, the IE switch closes the FTP connection and restarts.
Here, you specify whether or not the IE switch is accessible over TELNET.
Here, you specify whether or not the IE switch is accessible over SSH.
Here, you specify whether or not the IE Switch is reachable only over HTTPS. If you do not
select this option, it can also be reached with HTTP.
This enables / disables the e-mail function of the IE switch. For detailed information on this
functionality, refer to the section "Agent E-Mail Configuration menu item".
Here, you specify whether or not the IE switch stores log entries on a Syslog server. For
detailed information on this functionality, refer to the section "Agent Syslog Configuration
menu item".
An IE switch supports remote monitoring (RMON). Remote Monitoring allows diagnostic data
to be collected on the IE switch, prepared and read out using SNMP by a network
management station that also supports RMON. This diagnostic data, for example port-
related load trends, allow problems in the network to be detected early and eliminated. The
setting for RMON does not influence the statistics functions (see section "Statistics menu").