EasyManuals Logo

Siemens SIMATIC ET 200SP Function Manual

Siemens SIMATIC ET 200SP
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #352 background imageLoading...
Page #352 background image
Glossary
Communication
Function Manual, 11/2019, A5E03735815-AH
351
IO device, PROFINET IO device
Device in the distributed I/O of a PROFINET system that is monitored and controlled by an
IO controller (for example distributed inputs/outputs, valve islands, frequency converters,
switches).
IP address
Binary number that is used as a unique address in computer networks in conjunction with the
Internet Protocol (IP). It makes these devices uniquely addressable and individually
accessible. An IPv4 address can be evaluated using a binary subnet mask that results in a
network part or a host part as a structure. The textual representation of an IPv4 address
consists, for example, of 4 decimal numbers with the value range 0 to 255. The decimal
numbers are separated by periods.
IPv4 subnet mask
Binary mask, with which an IPv4 address (as a binary number) is divided into a "network
part" and a "host part".
ISO protocol
Communications protocol for message or packet-oriented transfer of data in an Ethernet
network. This protocol is hardware-oriented, very fast and allows dynamic data lengths. The
ISO protocol is suitable for medium to large volumes of data.
ISO-on-TCP protocol
Communications protocol capable of S7 routing for packet-oriented transfer of data in an
Ethernet network; provides network addressing. The ISO-on-TCP protocol is suitable for
medium and large volumes of data and allows dynamic data lengths.
Linear bus topology
Network topology characterized by the arrangement of the devices in a line (bus).
MAC address
Worldwide unique device identification for all Ethernet devices. The MAC address is
assigned by the manufacturer and has a 3-byte vendor ID and 3-byte device ID as a
consecutive number.
Master
Higher-level, active participant in the communication/on a PROFIBUS subnet. The master
has rights to access the bus (token) and can request and send data.
See also DP master

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C

Related product manuals