SNMP
Simple Network Management Protocol, uses the wireless UDP transport protocol. SNMP
works in much the same way as the client/server model. The SNMP manager monitors the
network nodes. The SNMP agents collect the various network-specific information in the
individual network nodes and makes this information available in a structured form in the MIB
(
Management Information Base). This information allows a network management system to
run detailed network diagnostics.
Subnet
Part of a network whose parameters must be matched up on the devices (for example in
PROFINET). A subnet includes the bus components and all connected stations. Subnets can
be linked together, for example using gateways or routers to form one network.
Switch
Network components used to connect several terminal devices or network segments in a
local network (LAN).
Switched communication
In addition to the device IP addresses of the CPUs, the redundant system S7-1500R/H
supports system IP addresses:
System IP address for the X1 PROFINET interfaces of the two CPUs (system IP address
X1)
System IP address for the X2 PROFINET interfaces of the two CPUs (system IP address
X2)
You use the system IP addresses for communication with other devices (for example, HMI
devices, CPUs, PG/PC). The devices always communicate over the system IP address with
the primary CPU of the redundant system. This ensures that the communication partner can
communicate with the new primary CPU (previously backup CPU) in the RUN-Solo system
state after failure of the original primary CPU in redundant operation.
System states
The system states of the redundant system S7-1500R/H result from the operating states of
the primary and backup CPUs. The term system state is used as a simplified expression that
refers to the operating states that occur simultaneously on both CPUs. The redundant
system S7-1500R/H has the system states STOP, STARTUP, RUN-Solo, SYNCUP and
RUN-Redundant.
TCP/IP
Transmission Control Protocol / Internet Protocol, connection-oriented network protocol,
generally recognized standard for data exchange in heterogeneous networks.

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C

Related product manuals