Technical specifications
8.2 General technical specifications
SIMATIC IPC847E
Operating Instructions, 10/2018, A5E43920357-AA
151
Noise emission
< 55 dB(A) at 25 °C according to DIN EN ISO 7779
all drives in operation, high load on CPU
< 45 dB(A) at 25 °C according to DIN EN ISO 7779
all drives in operation, low load on CPU
< 35 dB(A) at 25 °C according to DIN EN ISO 7779
Fan profile silent, idle desktop, drives are not active, standard AC power supply
Degree of protection
IP 41 (front) with closed front door
1
IP 20 on the rear according to EN 60529
Dust protection With closed front door
Filter class G2 EN 779; particles > 0.5 mm are 99% retained
Safety
Protection class
Protection class I compliant with IEC 61140
Degree of pollution
Device is designed for environments with pollution degree 2
Transient overvoltage Device is designed for connection to supply with overvoltage category II (transient
overvoltages up to 2500 V)
Safety regulations
IEC 61010-2-201
EN 61010-2-201
UL 61010-2-201
CSA C22.2 No 61010-2-201
1
Only with protected installation, see "Notes on ambient and environmental conditions
(Page 39)"

Table of Contents

Other manuals for Siemens SIMATIC IPC847E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC847E and is the answer not in the manual?

Siemens SIMATIC IPC847E Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC847E
CategoryIndustrial PC
LanguageEnglish

Related product manuals