Hardware description
2.2 Interface description
SIMOTION ADI4 - Analog Drive Interface for 4 Axes
20 Manual, 05/2009, 6FC5 297-0BA01-0BP6
Connectable measuring systems
Incremental encoder (TTL)
Differential transmission with RS 422 and operating voltage 5 V or 24 V:
Track A as true and inverted signal (U
a1
, /U
a1
)
Track B as true and inverted signal (U
a2
, /U
a2
)
Zero signal N as true and inverted signal (U
a0
, /U
a0
)
Maximum output frequency: 1.5 MHz
Phase shift of Track A to Track B: 90° ± 30°
Current consumption: Max. 300 mA
Encoders with distance-coded zero marks/reference marks are not generally enabled.
Absolute encoder (SSI)
Transmission method: Synchronous serial interface (SSI) according to RS 485 with 5 V
differential signal transmission (RS 422 standard)
Output signal: Data as true and inverted signal
Input signal: Shift clock as true and inverted signal
Data transmission format: "Pine tree"
Resolution: maximum of 25 bits
Maximum transmission rate: 1 Mbit/s
Current consumption: Max. 300 mA
The following SSI encoders are supported:
All SSI encoders in the pine tree format whose MsgLength is equal to the number of
"significant data bits":
25-bit with 12-bit multiturn and 13-bit single-turn information (setting of the
MsgLength 25)
21-bit with 8-bit multiturn and 13-bit single-turn information (setting of the
MsgLength 21)
21-bit with 9-bit multiturn and 12-bit single-turn information (setting of the
MsgLength 21)
13-bit with 13-bit single-turn information (setting of the MsgLength 13)
SSI encoder in the pine tree format with the following data:
25-bit with 12-bit multiturn and 12-bit single-turn (setting of the MsgLength 24)
21-bit with 8-bit multiturn and 12-bit single-turn information (setting of the
MsgLength 20)
13-bit with 12-bit single-turn information (setting of the MsgLength 12)
This applies as long as the encoder permits that not all available data is read!
All right-justified encoders that satisfy the first condition indicated above.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION ADI4 and is the answer not in the manual?

Siemens SIMOTION ADI4 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION ADI4
CategoryRecording Equipment
LanguageEnglish

Related product manuals