Parameter assignment
3.4 PROFIBUS parameters
SIMOTION ADI4 - Analog Drive Interface for 4 Axes
36 Manual, 05/2009, 6FC5 297-0BA01-0BP6
3.4.2 PROFIBUS address
Procedure
Inserting an ADI4 DP slave into the configuration will open the "Properties - PROFIBUS
Interface ADI4" dialog, "Parameters" tab:
3URSHUWLHV352),%86LQWHUIDFH$',
*HQHUDO
$GGUHVV
6XEQHW
QRWQHWZRUNHG
7UDQVPLVVLRQUDWH0ELWVV
3DUDPHWHUV
1HZ
'HOHWH
+HOS&DQFHO2.
3URSHUWLHV
Figure 3-1 PROFIBUS address
The displayed address value was automatically set by HW Config to the next available
PROFIBUS address within the configuration.
NOTICE
The PROFIBUS address of the ADI4 DP slave can be set to any value, in principle.
However, it must be ensured that the PROFIBUS address setting in HW Config matches
the DIP switch setting on the ADI4 DP slave:
There is no automatic adjustment!
The following data must agree:
SIMATIC S7 configuration ADI4 DP slave
PROFIBUS address
ADI4 module DIP switch S2
PROFIBUS address
After the dialog is confirmed with "OK", the "DP Slave Properties" dialog box is opened.
Continue with the parameter assignment for the message frame type.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION ADI4 and is the answer not in the manual?

Siemens SIMOTION ADI4 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION ADI4
CategoryRecording Equipment
LanguageEnglish

Related product manuals