Setting functions
8.6 Basic positioner and position control
Converter with control units CU250D-2
Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA
189
Table 8- 18 Job and parameters
Positioning ---
• Axis absolute or relative positioning.
• Rotary axis with modulo correction in a
positive or negative direction, absolute
positioning.
Travel to fixed
stop
Force [N] or torque [0.01 Nm] Traverse axis to a fixed stop:
• Linear axis with reduced force.
• Rotary axis with reduced torque.
See also the section: Travel to fixed stop
Endless travel --- Traverse the axis at the specified velocity to the
positive or negative end of the traversing range.
Go to Number
The converter then executes the next traversing
block with the specified number.
Set, reset
Set or reset internal signals in the converter:
• Output 1: r2683.10
• Output 2: r2683.11
You can interconnect the signals with digital
outputs of the converter or with bit 10 and 11 of
the positioning status word of the fieldbus.
See also the sections: Control and status word
for the positioner (Page 100) , Control and
status word 2 for the positioner (Page 104)
3 Set outputs 1 and 2
Jerk
Activate or deactivate jerk limiting.
See also the section: Limiting the traversing
profile (Page 162).
1 active