EasyManua.ls Logo

Siemens SINAMICS G120D - Page 195

Siemens SINAMICS G120D
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting functions
8.6 Basic positioner and position control
Converter with control units CU250D-2
Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA
195
Parameter
Meaning
p2623[0…n]
Traversing block, job mode
Value = 0000 cccc bbbb aaaa
cccc = 0000
Positioning
mode
Absolute
cccc = 0001
Relative
cccc = 0010 Absolute positive (only for rotary axis with modulo
correction)
cccc = 0011 Absolute negative (only for rotary axis with modulo
correction)
bbbb = 0000
Advance
condition
End
bbbb = 0001
Continue with stop
bbbb = 0010
Continue flying
bbbb = 0011
Continue external
bbbb = 0100
Continue external wait
bbbb = 0101
Continue external alarm
aaaa = 0001
Identifiers: Skip block
p2624
Sort traversing block
To sort the traversing blocks according to their block number: p2624 = 0 1.
p2625
Traversing block selection, bit 0
p2626
Traversing block selection, bit 1
p2627
Traversing block selection, bit 2
p2628
Traversing block selection, bit 3
p2631
Activate traversing block (0 1)
p2632
External block change evaluation
0
External block change via probe
1
External block change via BI: p2633
p2633
External block change (0 → 1)
p2640
Intermediate stop (0 signal)
p2641
Reject traversing job (0 signal)
p2646
Velocity override