Safety Integrated Extended Functions
6.8 Safe Speed Monitor (SSM)
Safety Integrated
Function Manual, 05/2010, A5E03264275A
101
Features
Safe monitoring of the speed limit specified in p9346 and p9546
Parameterizable hysteresis via p9347 and p9547
Variable PT1 filter via p9345 and p9545
Fail-safe output signal
No stop response
Overview of important parameters
p9345 SI Motion SSM (SGA n < nx) filter time (Motor Module)
p9545 SI Motion SSM (SGA n < nx) filter time (Control Unit)
p9346 SI Motion SSM velocity limit (Motor Module)
p9546 SI Motion SSM (SGA n < nx) velocity limit n_x (CU)
p9347 SI Motion velocity hysteresis (crosswise) (Motor Module)
p9547 SI Motion velocity hysteresis (crosswise) (Control Unit)
p9368 SI Motion SBR velocity limit (Motor Module)
p9568 SI Motion SBR velocity limit (CU)
r9722.0...15 CO/BO: SI Motion drive-integrated status signals