EasyManua.ls Logo

Siemens SINAMICS S150 - Safe Stop 1 (Basic Functions)

Siemens SINAMICS S150
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Acceptance test and acceptance report
10.5 Acceptance tests
Safety Integrated
Function Manual, 05/2010, A5E03264275A
267
10.5.1.2 Safe Stop 1 (Basic Functions)
Table 10- 9 "Safe Stop 1" function
No. Description Status
Note:
The acceptance test must be individually conducted for each configured control.
The control can be realized via terminals and/or via PROFIsafe.
Initial state
Drive in "Ready" state (p0010 = 0)
STO function enabled (on-board terminals / PROFIsafe p9601.0 = 1 and/or p9601.3 = 1)
Enable SS1 function (p9652 > 0, p9852 > 0)
No Safety faults and alarms (r0945[0...7], r2122[0...7]); see note "non-critical alarms" in
section Acceptance tests.
r9772.22 = r9872.22 = 0 (SS1 deselection via terminals – DI CU / EP terminal Motor
Module); only relevant for SS1 via terminal
r9772.23 = r9872.23 = 0 (SS1 deselection via PROFIsafe); only relevant for SS1 via
PROFIsafe
r9772.0 = r9772.1 = 0 (STO deselected and inactive – CU)
r9772.5 = r9772.6 = 0 (SS1 deselected and inactive – CU)
r9872.0 = r9872.1 = 0 (STO deselected and inactive – MM)
r9872.5 = r9872.6 = 0 (SS1 deselected and inactive – MM)
r9773.0 = r9773.1 = 0 (STO deselected and inactive – drive)
r9773.5 = r9773.6 = 0 (SS1 deselected and inactive – drive)
r9774.0 = r9774.1 = 0 (STO deselected and inactive - group); only relevant for grouping
1.
r9774.5 = r9774.6 = 0 (SS1 deselected and inactive - group); only relevant for grouping
Run the drive
Check whether the correct drive is operational
Select SS1 when you issue the traversing command and check the following:
The drive is braked along the OFF3 ramp (p1135)
Before the SS1 delay time (p9652, p9852) expires, the following applies:
r9772.22 = r9872.22 = 1 (SS1 selection via terminals – DI CU / EP terminal Motor
Module); only relevant for SS1 via terminal
r9772.23 = r9872.23 = 1 (SS1 selection via PROFIsafe); only relevant for SS1 via
PROFIsafe
r9772.0 = r9772.1 = 0 (STO deselected and inactive - CU)
r9772.5 = r9772.6 = 1 (SS1 selected and active – CU)
r9872.0 = r9872.1 = 0 (STO deselected and inactive – MM)
r9872.5 = r9872.6 = 1 (SS1 selected and active – MM)
r9773.0 = r9773.1 = 0 (STO deselected and inactive)
r9773.5 = r9773.6 = 1 (SS1 selected and active – drive)
2.
r9774.0 = r9774.1 = 0 (STO deselected and inactive - group); only relevant for grouping

Table of Contents