Commissioning
8.5 Commissioning TM54F by means of STARTER/SCOUT
Safety Integrated
206 Function Manual, 05/2010, A5E03264275A
8.5.4.2 Test stop mode 2
'2
'2
',
9H[W
70)
'2
'2
0
',
Figure 8-7 F-DO circuit, test stop mode 2
Test step
1)
L1+ L2+ Comment
1 OFF ON Synchronization
3 OFF OFF F-DIs 0 ... 4 Check at 0 V
5 ON ON F-DIs 5 ... 9 Check at 0 V
Test step
1)
DO+ DO- Expected response, DI signal
6 OFF OFF HIGH
8 ON ON LOW
10 OFF ON LOW
12 ON OFF LOW
14 OFF OFF HIGH
Test sequence for test stop mode 2
1)
You can find a complete list of the steps in the SINAMICS List Manual under message F35013.