Typicals and regulations
1.2 Safety of machinery in Europe
Safety Integrated
22 Function Manual, 05/2010, A5E03264275A
Systems for executing safety-related control
functions
EN ISO 13849-1 EN 62061
A Non-electrical (e.g. hydraulic, pneumatic) X Not covered
B Electromechanical (e.g. relay and/or basic
electronics)
Restricted to the designated
architectures (see comment 1)
and max. up to PL = e
All architectures and max. up to
SIL 3
C Complex electronics (e.g. programmable
electronics)
Restricted to the designated
architectures (see comment 1)
and max. up to PL = d
All architectures and max. up to
SIL 3
D A Typicals combined with B Typicals Restricted to the designated
architectures (see comment 1)
and max. up to PL = e
X
See comment 3
E C Typicals combined with B Typicals Restricted to the designated
architectures (see comment 1)
and max. up to PL = d
All architectures and max.
up to SIL 3
F C Typicals combined with A Typicals
or
C Typicals combined with A Typicals and B
Typicals
X
See comment 2
X
See comment 3
"X" indicates that the point is covered by this Typical.
Comment 1:
Designated architectures are described in Annex B of EN ISO 13849-1 and provide a simplified basis for the quantification.
Comment 2:
For complex electronics: Using designated architectures in compliance with EN ISO 13849-1 up to PL = d or every
architecture in compliance with EN 62061.
Comment 3:
For non-electrical systems: Use components that comply with EN ISO 13849-1 as sub-systems.