Acceptance test and acceptance report   
10.5 Acceptance tests 
  Safety Integrated 
286  Function Manual, 05/2010, A5E03264275A 
No.  Description  Status 
5.  Save/print the trace and add it to the acceptance report (refer to the example below) 
Deselect SLS and acknowledge Safety messages 
•  No Safety faults and alarms (r0945[0...7], r2122[0...7], r9747[0...7]) 
 
•  r0046.0 = 1 (drive in "switch-on inhibited" state) 
 
Acknowledge "switch-on inhibit" and run the drive 
6. 
•  Check the drive is moving. 
 
Example trace SLS with STOP B 
%LWWUDFNV
'ULYHBU>@6,0RWLRQGLDJQRVWLFVVSHHGDFWXDOORDGVLGHVSHHGYDOXHRQ&RQWURO8QLW
'ULYHBU>@6,0RWLRQGLDJQRVWLFVVSHHGFXUUHQW6%5VSHHGOLPLWRQ&RQWURO8QLW
6723$RU%DFWLYH
6HOHFW6/6ELW
6HOHFW6/6ELW
'HVHOHFW6/6
,QWHUQDOHYHQW
6/6DFWLYH
672DFWLYH
$FWLYH6/6OHYHOELW
$FWLYH6/6OHYHOELW
66DFWLYH
 
Figure 10-5  Example trace: SLS with STOP B