Acceptance test and acceptance report
10.5 Acceptance tests
Safety Integrated
298 Function Manual, 05/2010, A5E03264275A
%LWWUDFNV
'ULYHBU>@6,0RWLRQGLDJQRVWLFVVSHHGDFWXDOORDGVLGHVSHHGYDOXHRQ&RQWURO8QLW
'ULYHBU>@6,0RWLRQGLDJQRVWLFVVSHHGFXUUHQW6%5VSHHGOLPLWRQ&RQWURO8QLW
'HVHOHFW66
66DFWLYH
672DFWLYH
Figure 10-9 Example Trace SS1 without encoder
Trace evaluation:
SS1 function is selected (time axis 0 ms; see bit "deselection SS1")
Response bit "SS1 active" is set (time axis approx 20 ms)
The drive decelerates along the configured OFF3 ramp (p1135)
Recording of r9714[0] (orange curve) shows whether the OFF3 ramp is active
STO is activated (time axis approx. 720 ms; see bit "STO active"); at this point the speed
falls below the shutdown speed SS1 (p9560/p9360)
Brown curve: Envelope curve of function SBR (r9714[1]); faults are generated if this is
exceeded by the actual speed (r9714[0])
In contrast to the SBR for Safety with encoder, this curve is not tracked according to
actual speed but calculated using Safety parameters. Furthermore, this monitoring only
becomes active after a configurable time has elapsed (in this case the time is 250 ms).
Note
Small time differences (of the order of 2 to 3 Safety clock cycles (here up to 36 ms)) are
caused by internal calculations and do not present a problem.