Tables
12.4 List of predefined subprograms
Fundamentals
12-48 Programming Manual, 10.2004 Edition, 6FC5 298-7AB00-0BP1
9. Grinding
Vocabulary
word/
subprogram
identifier
1st parameter Explanation
GWPSON INT: Spindle
number
Grinding wheel peripheral speed ON: Constant grinding wheel peripheral speed ON
If the spindle number is not programmed, then grinding wheel peripheral speed is
selected for the spindle of the active tool.
GWPSOF INT: Spindle
number
Grinding wheel peripheral speed OFF. Constant grinding wheel peripheral speed
OFF.
If the spindle number is not programmed, grinding wheel peripheral speed is
deselected for the spindle of the active tool.
TMON INT: Spindle
number
Tool monitoring ON:
If no T number is programmed, monitoring is activated for the active tool.
TMOF INT: T number Tool monitoring OFF:
If no T number is programmed, monitoring is deactivated for the active tool.
10. Stock removal
Vocabulary
word/
subprogram
identifier
1st parameter 2nd parameter 3rd
parameter
4th
parameter
Explanation
CONTPRON REAL [ , 11]:
Contour table
CHAR: Stock
removal
method
"L":
Longitudinal
turning:
External
machining
"P": Face
turning:
External
machining
"N": Face
turning: Internal
machining:
"G":
Longitudinal
turning: Internal
machining
INT: Number
of relief cuts
INT: Status
of
calculation:
0:
unchanged
1:
Calculation
forwards
and
backwards
Contour preparation on: Activate
reference point editing
The contour programs and NC blocks
which are called in the following steps
are divided into individual movements
and stored in the contour table.
The number of relief cuts is returned.
CONTDCON REAL [ , 6]:
Contour table
INT:
0: in
programmed
direction
Contour decoding
The blocks for a contour are stored in a
named table with one table line per
block and coded to save memory.
EXECUTE INT: Error
status
EXECUTE: Activate program
execution.
This switches back to normal program
execution from reference point editing
mode or after setting up a protection
zone.