A Appendix
400
7SD610 Manual
C53000-G1176-C145-4
1495 BF Trip End fault stage (BF
EndFlt TRIP)
Breaker Failure OUT * ON * LED BO
1496 BF Pole discrepancy pickup (BF
CBdiscrSTART)
Breaker Failure OUT * ON
OFF
* LED BO
1497 BF Pole discrepancy pickup L1
(BF CBdiscr L1)
Breaker Failure OUT * ON
OFF
* LED BO
1498 BF Pole discrepancy pickup L2
(BF CBdiscr L2)
Breaker Failure OUT * ON
OFF
* LED BO
1499 BF Pole discrepancy pickup L3
(BF CBdiscr L3)
Breaker Failure OUT * ON
OFF
* LED BO
1500 BF Pole discrepancy Trip (BF
CBdiscr TRIP)
Breaker Failure OUT * ON * LED BO
1503 >BLOCK Thermal Overload Pro-
tection (>BLK ThOverload)
Therm. Overload SP * * * LED BI BO 167 3 1 Yes
1511 Thermal Overload Protection
OFF (Th.Overload OFF)
Therm. Overload OUT ON
OFF
* * LED BO 167 11 1 Yes
1512 Thermal Overload Protection
BLOCKED (Th.Overload BLK)
Therm. Overload OUT ON
OFF
ON
OFF
* LED BO 167 12 1 Yes
1513 Thermal Overload Protection
ACTIVE (Th.O/L ACTIVE)
Therm. Overload OUT ON
OFF
* * LED BO 167 13 1 Yes
1515 Th. Overload: Current Alarm (I
alarm) (Th.O/L I Alarm)
Therm. Overload OUT ON
OFF
* * LED BO 167 15 1 Yes
1516 Th. Overload Alarm: Near
Thermal Trip (Th.O/L Θ Alarm)
Therm. Overload OUT ON
OFF
* * LED BO 167 16 1 Yes
1517 Th. Overload Pickup before trip
(Th.O/L Pickup)
Therm. Overload OUT ON
OFF
* * LED BO 167 17 1 Yes
1521 Th. Overload TRIP command
(Th.O/L TRIP)
Therm. Overload OUT * ON * LED BO 167 21 2 Yes
2054 Emergency mode (Emer. mode) Device OUT ON
OFF
ON
OFF
* LED BO 192 37 1 Yes
2701 >AR: Switch on auto-reclose
function (>AR on)
Auto Reclose SP * * * LED BI BO 40 1 1 Yes
2702 >AR: Switch off auto-reclose
function (>AR off)
Auto Reclose SP * * * LED BI BO 40 2 1 Yes
2703 >AR: Block auto-reclose function
(>AR block)
Auto Reclose SP ON
OFF
**LEDBIBO4031Yes
2711 >External start of internal Auto
reclose (>AR Start)
Auto Reclose SP * ON * LED BI BO 40 11 2 Yes
2712 >AR: External trip L1 for AR start
(>Trip L1 AR)
Auto Reclose SP * ON * LED BI BO 40 12 2 Yes
2713 >AR: External trip L2 for AR start
(>Trip L2 AR)
Auto Reclose SP * ON * LED BI BO 40 13 2 Yes
2714 >AR: External trip L3 for AR start
(>Trip L3 AR)
Auto Reclose SP * ON * LED BI BO 40 14 2 Yes
2715 >AR: External 1pole trip for AR
start (>Trip 1pole AR)
Auto Reclose SP * ON * LED BI BO 40 15 2 Yes
2716 >AR: External 3pole trip for AR
start (>Trip 3pole AR)
Auto Reclose SP * ON * LED BI BO 40 16 2 Yes
2727 >AR: Remote Close signal (>AR
RemoteClose)
Auto Reclose SP * ON * LED BI BO 40 22 2 Yes
2731 >AR: Sync. release from ext.
sync.-check (>Sync.release)
Auto Reclose SP * * * LED BI BO 40 31 2 Yes
2737 >AR: Block 1pole AR-cycle
(>BLOCK 1pole AR)
Auto Reclose SP ON
OFF
**LEDBIBO40321Yes
2738 >AR: Block 3pole AR-cycle
(>BLOCK 3pole AR)
Auto Reclose SP ON
OFF
**LEDBIBO40331Yes
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log On/Off
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation