A.8 Information List
401
7SD610 Manual
C53000-G1176-C145-4
2739 >AR: Block 1phase-fault AR-
cycle (>BLK 1phase AR)
Auto Reclose SP ON
OFF
**LEDBIBO40341Yes
2740 >AR: Block 2phase-fault AR-
cycle (>BLK 2phase AR)
Auto Reclose SP ON
OFF
**LEDBIBO40351Yes
2741 >AR: Block 3phase-fault AR-
cycle (>BLK 3phase AR)
Auto Reclose SP ON
OFF
**LEDBIBO40361Yes
2742 >AR: Block 1st AR-cycle (>BLK
1.AR-cycle)
Auto Reclose SP ON
OFF
**LEDBIBO40371Yes
2743 >AR: Block 2nd AR-cycle (>BLK
2.AR-cycle)
Auto Reclose SP ON
OFF
**LEDBIBO40381Yes
2744 >AR: Block 3rd AR-cycle (>BLK
3.AR-cycle)
Auto Reclose SP ON
OFF
**LEDBIBO40391Yes
2745 >AR: Block 4th and higher AR-
cycles (>BLK 4.-n. AR)
Auto Reclose SP ON
OFF
**LEDBIBO40401Yes
2746 >AR: External Trip for AR start
(>Trip for AR)
Auto Reclose SP * ON * LED BI BO 40 41 2 Yes
2747 >AR: External pickup L1 for AR
start (>Pickup L1 AR)
Auto Reclose SP * ON * LED BI BO 40 42 2 Yes
2748 >AR: External pickup L2 for AR
start (>Pickup L2 AR)
Auto Reclose SP * ON * LED BI BO 40 43 2 Yes
2749 >AR: External pickup L3 for AR
start (>Pickup L3 AR)
Auto Reclose SP * ON * LED BI BO 40 44 2 Yes
2750 >AR: External pickup 1phase for
AR start (>Pickup 1ph AR)
Auto Reclose SP * ON * LED BI BO 40 45 2 Yes
2751 >AR: External pickup 2phase for
AR start (>Pickup 2ph AR)
Auto Reclose SP * ON * LED BI BO 40 46 2 Yes
2752 >AR: External pickup 3phase for
AR start (>Pickup 3ph AR)
Auto Reclose SP * ON * LED BI BO 40 47 2 Yes
2781 AR: Auto-reclose is switched off
(AR off)
Auto Reclose OUT ON
OFF
**LEDBO40811Yes
2782 AR: Auto-reclose is switched on
(AR on)
Auto Reclose IntSP * * * LED BO 192 16 1 Yes
2783 AR: Auto-reclose is blocked (AR
is blocked)
Auto Reclose OUT ON
OFF
**LEDBO40831Yes
2784 AR: Auto-reclose is not ready (AR
not ready)
Auto Reclose OUT * ON * LED BO 192 130 1 Yes
2787 AR: Circuit breaker not ready (CB
not ready)
Auto Reclose OUT * * * LED BO 40 87 1 Yes
2788 AR: CB ready monitoring window
expired (AR T-CBreadyExp)
Auto Reclose OUT * ON * LED BO 40 88 2 Yes
2796 AR: Auto-reclose ON/OFF via BI
(AR on/off BI)
Auto Reclose IntSP * * * LED BO
2801 AR: Auto-reclose in progress (AR
in progress)
Auto Reclose OUT * ON * LED BO 40 101 2 Yes
2809 AR: Start-signal monitoring time
expired (AR T-Start Exp)
Auto Reclose OUT * ON * LED BO 40 174 2 Yes
2810 AR: Maximum dead time expired
(AR TdeadMax Exp)
Auto Reclose OUT * ON * LED BO 40 175 2 Yes
2818 AR: Evolving fault recognition
(AR evolving Flt)
Auto Reclose OUT * ON * LED BO 40 118 2 Yes
2820 AR is set to operate after 1p trip
only (AR Program1pole)
Auto Reclose OUT * * * LED BO 40 143 1 Yes
2821 AR dead time after evolving fault
(AR Td. evol.Flt)
Auto Reclose OUT * ON
OFF
* LED BO 40 197 2 Yes
2839 AR dead time after 1pole trip
running (AR Tdead 1pTrip)
Auto Reclose OUT * ON * LED BO 40 148 2 Yes
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log On/Off
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation