A - 20
Siemens AG May 1998
Alarms from the bay unit for LC display and binary inputs and outputs
FNo – Function number of the alarm
MW – measured value
EA – E: marshallable to binary input
A: marshallable to binary output (LED, alarm relay, command relay)
Table A.9.10 Marshallable output functions
FNo Short text Logical functions
5
56
60
143
145
161
190
511
601
602
603
604
608
609
610
611
612
613
644
651
652
653
654
1156
1174
7000
7001
7002
7003
7004
7005
7006
7007
7008
7009
7020
7021
7022
>LED-ackn
REBOOT
LED-ackn
15V-superv.
0V-superv.
Meas in sup
Fail Com.CU
Com Trip
IL1 [%] =
IL2 [%] =
IL3 [%] =
IE [%] =
IDL1 [%]=
IDL2 [%]=
IDL3 [%]=
ISL1 [%]=
ISL2 [%]=
ISL3 [%]=
f [%]=
IL1 =
IL2 =
IL3 =
IE =
>CB test
CB test
>Isol1-Closed
>Isol1-Open
>Isol2-Closed
>Isol2-Open
>Isol3-Closed
>Isol3-Open
>Isol4-Closed
>Isol4-Open
>Isol5-Closed
>Isol5-Open
>CBF L1
>CBF L2
>CBF L3
>Reset LED indications
Initial start-up
Reset LED indications
Failure supply voltage 15 V
Failure offset monitoring 0 V
Measured value supervision
Data communication to master unit disturbed
Protection common trip
Actual current of phase L1 [%]
Actual current of phase L2 [%]
Actual current of phase L3 [%]
Actual earth current [%]
Operational measured value diff current phase L1 in %
Operational measured value diff current phase L2 in %
Operational measured value diff current phase L3 in %
Operational measured value stab current phase L1 in %
Operational measured value stab current phase L2 in %
Operational measured value stab current phase L3 in %
Actual frequency f [%]
Actual current in phase L1
Actual current in phase L2
Actual current in phase L3
Actual earth current
>Start three-pole circuit breaker test
Circuit breaker test running
>Isolator status signal Closed for isolator 1
>Isolator status signal Open for isolator 1
>Isolator status signal Closed for isolator 2
>Isolator status signal Open for isolator 2
>Isolator status signal Closed for isolator 3
>Isolator status signal Open for isolator 3
>Isolator status signal Closed for isolator 4
>Isolator status signal Open for isolator 4
>Isolator status signal Closed for isolator 5
>Isolator status signal Open for isolator 5
Circuit breaker test phase L1
Circuit breaker test phase L2
Circuit breaker test phase L3
EA
A
A
A
A
A
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
www . ElectricalPartManuals . com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7SS52 and is the answer not in the manual?

Siemens SIPROTEC 7SS52 Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 7SS52
CategoryProtection Device
LanguageEnglish

Related product manuals