3RT1/3RH1 contactors
SIRIUS System Manual
GWA 4NEB 430 0999-02b
3-47
Compensating for dif-
ferent depths
In star-delta combinations with contactors of different frame sizes, it is nec-
essary to compensate for the mounting depth of the smaller contactor.
One frame size is the maximum difference possible.
The following depth compensation must be made for a mechanical interlock
attached at the side:
S2-S2-S0: K3: 1.5 mm; K2: 0 mm
S3-S3-S2: K3: 0 mm; K2: 27.5 mm
Mounting and connec-
tion
The star-delta combinations have screw-type connections that are suitable
for both screw-on and snap-on mounting on the 35 mm rail.
Conductor cross-sec-
tions
The permissible conductor cross-sections of the star-delta combinations cor-
respond to those of the basic units for the corresponding frame size.
Circuit diagrams
Main circuit: S00, S0, S2, S3
Figure 3-25: Star-delta combination, main circuit (frame sizes S00 to S3)
S2 and S3
S00 S0
L1
L2
L3
F1
K1 K3
M
3
~
NSB00642
U1
V1
W1
F0
K2
135
2
46
W2
U2
V2
135
246
M
U1
V1
W1
W2
U2
V2
3AC 50Hz ...V
3
~
L1
L2
L3
F1
K1 K3
M
3
~
NSB00645
U1
V1
W1
F0
K2
135
2
46
W2
U2
V2
135
246
M
U1
V1
W1
W2
U2
V2
3AC 50Hz ...V
3
~
L1
L2
L3
F1
K1 K3
M
3
~
NSB00648
U1
V1
W1
F0
K2
135
2
46
W2
U2
V2
135
246
M
U1
V1
W1
W2
U2
V2
3AC 50Hz ...V
3
~
F0

Table of Contents

Other manuals for Siemens SIRIUS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIRIUS and is the answer not in the manual?

Siemens SIRIUS Specifications

General IconGeneral
Product brand nameSiemens
SeriesSIRIUS
Coil Voltage24V DC, 110V AC, 230V AC
Switching CapacityUp to 10A
Mounting TypeDIN rail
Product designationSIRIUS
Contact MaterialSilver alloy
Contact RatingVaries depending on the specific SIRIUS relay model (e.g., 6 A at 250 V AC, 10 A at 250 V AC)
Switching VoltageVaries depending on the specific SIRIUS relay model (e.g., 250 V AC, 400 V AC)
Mechanical LifeUp to 10 million operations
Electrical LifeUp to 100, 000 operations
Operating Temperature-25°C to +55°C
Protection ClassIP20
Size of relay baseVaries depending on the specific SIRIUS relay model

Related product manuals