In devices where a plug is already mounted on the enclosure, the connection is made via a cable
socket.
1. Thread the parts of the cable socket as described by the manufacturer of the cable socket.
2. Strip approximately 18 mm of the bus cable .
3. Twist the shield.
4. Thread the shield in the insulating sleeve.
5. Draw 8 mm of shrink sleeve over the cable, wires and shield up to the reference edge .
6. Screw the cable ends and the shield in the pin insert.
7. Fasten the parts of the cable socket as described by the manufacturer.


Figure 6-10 Preparing the connecting cable
Reference edge for stripping Insulating sleeve over the shield
Reference edge for the dimension spec‐
i󹪝cations for cable assembly
Shrink sleeve
Assignment
Layout for M12 device plug
Assignment diagram M12-cable socket
M12 x 1 thread Positioning slot
Positioning catch
Connecting
6.10 Connect M12 cable socket to the cable
SITRANS TH100/TH320/TH420/TR320/TR420/TF320/TF420 with 4 to 20 mA/HART
102 Operating Instructions, 05/2020, A5E41864807-AB