Siemens SITRANS T Series - Page 213

Siemens SITRANS T Series
236 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FM/CSA SITRANS TH/TR SITRANS TF Display
Name - CL I, Div 1, GP ABCD T6 … T4
Type 4X
CL II/III, Div 1, GP EFG T6 … T4
Type 4X
CL II/III, Div 2, GP FG T6 … T4
Type 4X
or
AEx db IIC T6 ... T4 Gb
AEx tb IIIC T100°C Db
AEx tc IIIC T100°C Dc
CL I, Div 1, GP ABCD T6 … T4
Type 4X
CL II/III, Div 1, GP EFG T6 … T4
Type 4X
CL II/III, Div 2, GP FG T6 … T4
Type 4X
Ex db IIC T6 ... T4 Gb
Ex tb IIIC T100°C Db
Ex tc IIIC T100°C Dc
-
Output terminals SI‐
TRANS TF single cham‐
ber housing: 1, 2
SITRANS TF dual cham‐
ber housing: (+) and
(-)
- U
max
= 37 V DC -
Permissible ambient
temperature
- -50 … +85 °C (-58 … +185 °F)
Temperature class T4/T100 °C
1)
-50 … +60 °C (-58 … +140 °F)
Temperature class T6
-
Non-hazardous areas
Output terminals
SITRANS TH/
SITRANS TF single
chamber housing: 1, 2
SITRANS TR: 3, 4
SITRANS TF dual cham‐
ber housing: (+) and
(-)
U
max
≤ 37 V DC
Permissible ambi‐
ent temperature
-50 °C to +85 °C (-58 °F to +185 °F) -40 °C to +85 °C (-40 °F
to +185 °F)
1)
A SITRANS TF display or a SITRANS TF in a dual chamber housing has the minimum permissible ambient temperature of -40 °C.
See also
Certi󹪝cates (
http://www.siemens.com/processinstrumentation/certi󹪝cates)
Technical data
12.2 SITRANS TH320/TH420/TR320/TR420/TF320/TF420
SITRANS TH100/TH320/TH420/TR320/TR420/TF320/TF420 with 4 to 20 mA/HART
Operating Instructions, 05/2020, A5E41864807-AB 213