Code Command explanation Comment
72
Delete logs in MMC
The logs stored in the Micro Memory Card are
deleted.
Service operation
73
Delete log in MMC (Trace)
The recorded data (trace function) stored in the
Micro Memory Card are deleted.
74
Delete log in RAM (Trace)
The stored data (trace function) in the RAM memory
are deleted.
75
Format MMC
The Micro Memory Card parameters are defined
corresponding with the definitions in the module
data. All of the stored content in the MMC is deleted.
Service operation
76
Delete all MMC data (log data, measurement
data, …)
The data stored in the Micro Memory Card are
deleted.
Service operation
Scale commands
100
Switch belt on
Used for switching the belt belt on
(The belt control bit is set in CONTI status)
101
Switch belt off
Used for switching the transport belt off
(The belt control bit is deleted in CONTI status) and
if necessary, the running totalizing procedure is
stopped, the discharge organ is switched off at the
same time.
102
Switch on totalizing
This is used for starting the totalization using the
flowrate in the 8 distribution memory locations
(is only used if the belt control is switched on)
103
Switch off totalizing/Switch off loading
This is used for stopping the totalizing, the flowrate
continues to be measured and there is no integration
into the distribution memory. Loading operation is
ended.
104
Switch on dosing (belt scale)
Activate discharge organ (is only used if the belt
control is switched on)
6-92 SIWAREX FTC

Table of Contents