MESSAGES AND DIAGNOSIS
Error
No.
Data and op
erating
errors
- Meaning
Explanation
119 Tilt angle implausible
Tilt angle of the belt implausible
(must be larger than 0).
120
121
122 Current value
definition is not
plausible
Current value definition (actuation signal) in the device
characteristic curve DR 11 is not plausible.
123 Operating point in the
characteristic curve is
not plausible
The definition of the operating point in the device characteristic
curve or in the material characteristic curve is not plausible.
124 Reserved
Reserved
125 Flow rate setpoint not
plausible.
The setpoint in DR 20 is not plausible.
143 Load amount too low
(belt scale)
The defined load amount is too low. For belt scale only.
150 Command impossible
since SIMATIC CPU
is in STOP
Command impossible since SIMATIC CPU is in STOP
166 Date Time implausible The date or time definition is not plausible. Correct the
definition.
The following are allowed:
Year: 0..99
Month: 1..12
Day: 1..28/29/30/31
(depending on the month)
Hour: 0..23
Minute: 0..59
Second: 0..59
Weekday: 1..7
167 Time definition
implausible
The definition for a time entry is not plausible. Check the
following conditions:
DR 6 measuring time for the flow rate is not in permitted
range
DR 6 : Filling time does not match maximum filling time
DR 6: Inhibit time does not match settling time
DR 12: Control cycle time, Integration time or
differentiation time not plausible
168 Percentage default
value incorrect
The percentage default value is not plausible.
169 Negative default value
not permitted
Negative default value not permitted Change the definition.
170 Number range for
weighing values
exceeded
The numeral range for a definition is invalid. Permitted values
are -100 000 000 and lower than 100 000 000.
171 Checksum error
Checksum error in data record 26.
The data was falsified or the DR versions to not match.
SIWAREX FTC