Name Type Address Default Range of Values / Meaning Reference
Definition of the process
alarm 6
WORD DBW020 0 Value 0 - No process alarm generation
Value range 1 – 0FFh
Number of the technical error
Value range 100h – 13Fh
100h+ 0...1Fh Bit-No. NAWI-status bit - coming
100h+ 20h...3Fh Bit-No. Conti status bit-coming
Value range 200h – 23Fh
200h+ 0...1Fh Bit-No. NAWI status bit - going
200h+ 20h...3Fh Bit-Nr. Conti status bit-going
5.6.6
Definition of the process
alarm 7
WORD DBW022 0 Value 0 - No process alarm generation
Value range 1 – 0FFh
Number of the technical error
Value range 100h – 13Fh
100h+ 0...1Fh Bit-No. NAWI-status bit - coming
100h+ 20h...3Fh Bit-No. Conti status bit-coming
Value range 200h – 23Fh
200h+ 0...1Fh Bit-No. NAWI status bit - going
200h+ 20h...3Fh Bit-Nr. Conti status bit-going
5.6.6
S7 - FB Life bit
monitoring time
TIME DBD024 0 0 = S7- Life bit monitor switched off
1 to n = Monitoring time [msec]
5.6.7
Analog output 0
Weight for zero point
(0 or 4 mA)
REAL DBD028 0 Value output with the 0 or 4 mA
5.6.8
Reference for end value
(20 mA)
REAL DBD032 0 Value output with the 20 mA.
5.6.9
Replacement value for
the analogue output at
OD
REAL DBD036 0 Replacement value which is output with an active
OD signal if the parameters are defined
respectively
5.6.10
Source for the analog
output
BYTE DBB040 0 0 = Control signals-SIMATIC
1 = ext. default value through DR 17
2 = Gross
3 = Net
4 = Belt speed
5 = Flow rate 1
6 = Belt load Other definitions not allowed
7 = Actuation signal PID controller
5.6.11
Current range for the
analogue output
BYTE DBB041 0 Bit 0:
0: 0 .. 20mA
1: 4 .. 20mA
Bit 1 – 7 unused
5.6.12
RS232 0
RS232-printer baud rate
BYTE DBB042 3 0 = 1200 Bit/sec.
1 = 2400 Bit/sec.
2 = 4800 Bit/s
3 = 9600 Bit/s
Other definitions not permitted.
5.6.13
5-58 SIWAREX FTC