EasyManua.ls Logo

Siemens SIWAREX FTC - Page 72

Siemens SIWAREX FTC
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Name Type Address Default Range of Values / Meaning Reference
Definition of the digital
output 5
BYTE DBB052 0FFh Value range 00h – 3Fh
0...1Fh Bit-No. NAWI status flag
20h...3Fh Bit-No. Conti status flag
FFh output always inactive
5.6.19
Definition of the digital
output 6
BYTE DBB053 0FFh Value range 00h – 3Fh
0...1Fh Bit-No. NAWI status flag
20h...3Fh Bit-No. Conti status flag
FFh output always inactive
5.6.19
Definition of the digital
output 7
BYTE DBB054 0FFh Value range 00h – 3Fh
0...1Fh Bit-No. NAWI status flag
20h...3Fh Bit-No. Conti status flag
FFh output always inactive
5.6.19
Definition of the digital
output 8
BYTE DBB055 0FFh Value range 00h – 3Fh
0...1Fh Bit-No. NAWI status flag
20h...3Fh Bit-No. Conti status flag
FFh output always inactive
5.6.19
Level definition for digital
outputs 1....8
BYTE DBB056 0 Bit 0: DO1 -> 0 = high active: 1 = low active
....
Bit 7: DO8 -> 0 = high active: 1 = low active
5.6.20
Replacement values for
digital outputs 1 .... 8
upon fault or OD signal
BYTE DBB057 0 Bit 0: Replacement value digital output 1
....
Bit 7: Replacement value digital output 8
5.6.21
Activate - Digital output
replacement values for
operational faults
BYTE DBB058 0 Bit 0:
0: Replacement value output for operating error
deactivated
1: Replacement value for operating error
activated
Bit 1 - 7 not used
5.6.22
Reserve 3
BYTE DBB059 0 Reserve 3
Digital inputs 0
Definition of digital input 1
BYTE DBB060 0 0 = No command
1- 254 = Command code
5.6.23
Definition of the digital
input 2
BYTE DBB061 0 0 = No command
1- 254 = Command code
5.6.23
Definition of the digital
input 3
BYTE DBB062 0 0 = No command
1- 254 = Command code
5.6.23
Definition of the digital
input 4
BYTE DBB063 0 0 = No command
1- 254 = Command code
5.6.23
Definition of the digital
input 5
BYTE DBB064 0 0 = No command
1- 254 = Command code
5.6.23
Definition of the digital
input 6
BYTE DBB065 0 0 = No command
1- 254 = Command code
5.6.23
Definition of the digital
input 7
BYTE DBB066 0 0 = No command
1- 254 = Command code
5.6.23
Level definition for digital
inputs 1...7
BYTE DBB067 0 Bit 0: Digital input 1 -> 0 = high active: 1 = low
active
....
Bit 6: Digital input 7 -> 0 = high active: 1 = low
active
Bit 7: Not used
5.6.24
Reserved
TIME DBD068 0 Reserved
5-60 SIWAREX FTC

Table of Contents

Related product manuals