TC35i AT Command Set
5.3 AT^SPIC
s
m
obil
e
TC35i_ATC_V02.07 Page 117 of 439 1/30/04
Confidential / Released
See also Chapters AT+CLCK, AT+CPIN, AT+CPIN2, AT+CPWD, AT^SLCK for further information on locks and
passwords.
Examples
EXAMPLE 1
The client fails to provide a correct SIM PIN three times The counter decreases each time. After the counter
reaches zero, the SIM PUK is required. After failure to enter a correct SIM PUK, the counter decreases.
at+cpin?
+CPIN: SIM PIN
OK
(currently required password is PIN1)
at^spic
^SPIC: 3
OK
(3 attempts left)
at+cpin=9999
+CME ERROR: incorrect password
at^spic
^SPIC: 2
(2 attempts left)
OK
at+cpin=9999
+CME ERROR: incorrect password
OK
at^spic
^SPIC: 1
OK
at+cpin=9999
+CME ERROR: incorrect password
at+cpin?
+CPIN: SIM PUK
OK
(now required password is PUK 1)
at^spic
^SPIC: 10
OK
(10 attempts left for PUK 1)
at+cpin=01234567,1234
+CME ERROR: incorrect password
at^spic
^SPIC: 9
OK
(9 attempts left for PUK 1)